Retour aux alertes CVE
CVE-2026-48756

CVE-2026-48756

Publiée 2 weeks ago Fiche NVD officielle

Qu'est-ce que c'est ?

Incus is a system container and virtual machine manager. Prior to version 7.1.0, `(*backend).CreateCustomVolumeFromBackup` in `internal/server/storage/backend.go` contains an unguarded `*time.Time` dereference on the `ExpiresAt` field of every volume-snapshot entry in an imported custom-volume backup. An authenticated user with `can_create_storage_volumes` permission on any project can crash the `incusd` daemon by uploading a backup tarball whose `volume_snapshots[*].expires_at` field is absent. This is a sibling-field variant of GHSA-r7w7-mmxr-47r9 (CVE-2026-40197). Commit `985a1dedf9f3e7ba729c93b654905ed510de25c2` added `if s == nil` at the top of the loop body, but did not guard the adjacent `*snapshot.ExpiresAt` deref 19 lines later. Every other consumer of `Config.VolumeSnapshots[i].ExpiresAt` in this same file already gates the deref with a nil-check — the asymmetric guard is the bug. Version 7.1.0 contains an updated patch.

Technologies affectées

Non précisé par la fiche NVD.

Recommandation

Vérifie la disponibilité d'un correctif pour la technologie concernée et applique-le dès que possible. Consulte la fiche NVD pour les références officielles du fournisseur.

Exploits publics connus (0)

Aucun proof-of-concept public trouvé sur GitHub à ce jour. Ça peut changer : les PoC sont souvent publiés plusieurs jours ou semaines après la divulgation.